By superlite block an oldcastle company.
Masonry block with integral insulation.
We insert insulation into the cores of standard cmu.
The assembly provides a wall system capable of achieving higher thermal r values than conventional masonry with no effect on the structural integrity of masonry construction.
Specially designed concrete masonry unit and individually molded insulation insert.
Examples include insulation placed in concrete masonry cores and continuous insulation in a masonry cavity wall note that an insulated masonry cavity wall can also be considered as exterior insulation if the thermal mass effect of the veneer is disregarded.
Core fill 500 is a non expanding aminoplast foam that looks like white shaving cream.
7 3 alternative insulation products integral to the cmu block include a molded foam slotted inserts and b injectable resinous foam.
The foam is injected under pressure into the empty cores of masonry walls.
The components of this system from interior to exterior are described in fig.
Core fill 500 masonry foam insulation core fill 500 is america s leading foam insulation for concrete block precast concrete and hollow cavity brick walls.
Integral insulation refers to insulation placed between two layers of thermal mass.
203 mm nominal thickness must have continuous r 5 minimum insulation in addition to the integral insulation to comply i e the r value of the integral insulation.
R value cavity na and r value continuous r 5.
It saves materials and labour improves energy efficiency and durability.
Korfil hi r masonry wall system.
The integra wall system is an engineered post tensioned masonry wall system.
Astra glaze sw glazed units are pre faced architectural concrete masonry blocks with a thermoset glazing compound permanently molded on one or more faces.
Images courtesy of masonry magazine and concrete products group respectively.
This glazing compound is cured and heat treated in gas fired tunnel kilns thus becoming an integral part of the unit.
View block wall colors shapes system applications specifications details lineart download and more.
Depending on the density of the blocks an 8 inch thick block wall without any other type of insulation has a thermal resistance value between r 1 9 and r 2 5.
Masonry system 4 is a mass wall system with a single wythe concrete masonry unit cmu wall structure often comprised of split face block and integral insulation.
This unit achieves higher r values than standard cmu insulation.
With integral insulation and no framing are.